Your new White-Rodgers 7-Day Digital Thermostat uses the technology of a solid-land microcomputer to provide precise time/temperature control. This thermostat offers you the flexibility to pattern heating and cooling programs that fit your needs.
Features:

  • Separate program for each mean solar day of the week with four separate time/temperature periods per 24-hour interval
  • Simultaneous estrus and cool program storage
  • Preprogrammed temperature command
  • Backlit display
  • LCD continuously displays setpoint and alternately displays time and room temperature
  • Temperature override until next program menses
  • Transmission program override (Concur temperature)
  • Temporary Agree
  • °F/°C convertibility
  • Temperature range 45° to 90°F
  • RC, RH, C, W, Y, Thousand , O and B terminals
  • Optional C terminal (Dual Power selection)
  • B and O terminals for single stage heat pumps (no auxiliary heat) or damper operation
  • Program storage in instance of power loss
  • two "AA" Analeptic ®alkaline batteries included

PRECAUTIONS

This thermostat is intended for utilize with a low voltage system; do not use this thermostat with a line voltage arrangement. If in doubt nearly whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or electrician.

Exercise not exceed the specification ratings.
All wiring must conform to local and national electrical codes and ordinances.
This control is a precision instrument and should exist handled carefully. Rough handling or distorting components could cause the command to malfunction.

Warning Icon CAUTION
To prevent electrical shock and/or equipment damage, disconnect electric power to the organisation at the primary fuse or circuit breaker box until installation is complete.

Warning Icon WARNING
Do not use on circuits exceeding specified voltage.  Higher voltage volition impairment control and could cause shock or fire hazards.
Do not short out terminals on gas valve or chief command to test. Short or incorrect wiring will harm the thermostat and could cause personal injury and/or holding damage.
Thermostat installation and all components of the system shall conform to Class Two circuits per the NEC code.

Warning Icon Alert
For California Residents: This production contains a chemic known to the state of California to cause cancer and birth defects and other reproductive harm.

SPECIFICATIONS

Electric Data
Electrical Rating:
viii to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
i.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range: 45°F to ninety°F (7°C to 32°C)
Operating Ambient Temperature Range: 32°F to 105°F
Operating Humidity Range: 0 to xc% RH (non-condensing)
Aircraft Temperature Range: -4°F to 149°F

APPLICATIONS
For utilize with:

  • Standard rut/absurd or heat but systems
  • Electric estrus systems
  • Gas or oil-fired systems
  • Gas systems with intermittent ignition devices (I.I.D.) and/or vent dampers
  • Hydronic (hot water or steam) systems
  • Single-phase oestrus pump systems (no auxiliary heat)
  • Millivolt systems

Exercise NOT Use WITH:

  • Multi-stage systems
  • Systems exceeding 30 VAC and 1.5 amps
  • 3-wire zoned hydronic heating systems

INSTALLATION

REMOVE Old THERMOSTAT

  1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected.
  2. Remove the forepart comprehend of the old thermostat. With wires withal attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermostat and the wall mounting plate as an assembly.
  3. Identify each wire attached to the quondam thermostat using the labels enclosed with the new thermostat.
  4. Disconnect the wires from the old thermostat i at a time. DO Not LET WIRES FALL BACK INTO THE WALL.
  5. Install a new thermostat using the post-obit procedures.

Attention!
This product does not comprise mercury. However, this product may supercede a unit that contains mercury.
Practise not open mercury cells. If a jail cell becomes damaged, practise not touch any spilled mercury. Wearing nonabsorbent gloves, take up the spilled mercury with sand or other absorbent textile and place information technology into a container that tin be sealed. If a jail cell becomes damaged, the unit should be discarded.
Mercury must not be discarded in household trash. When the unit this production is replacing is to be discarded, place in a suitable container. Refer to www.thermostat-recycle.org  for a location to send products containing mercury.

Electrical Oestrus OR SINGLE-STAGE
HEAT PUMP SYSTEMS
This thermostat is configured from the factory to operate a heat/ cool, fossil fuel (gas, oil, etc.), forced-air system. Information technology is configured correctly for any system that DOES Non  require the thermostat to energize the fan on a call for heat. If your system is an electric heat or rut-pump arrangement that REQUIRES the thermostat to plough on the fan on a call  for heat, locate the ELECTRIC/GAS switch on the back of the thermostat (run into fig. 1) and switch it to the Electric position. This will permit the thermostat to energize the  fan immediately on a call for estrus. If yous are  unsure if the heating/cooling system requires the thermostat to control the fan, contact a qualified heating and ac
service person.
Adhere THERMOSTAT BASE TO WALL

  1. Remove the packing material from the thermostat. Gently pull the cover straight off the base. Forcing or prying on the thermostat volition cause damage to the unit. If necessary,  move the electric heat switch (meet ELECTRIC HEAT SYSTEMS, above).
  2. Connect wires beneath terminal screws on the base of operations using the advisable wiring schematic (see figs. ii through seven).
  3. Place base over hole in wall and mark mounting hole locations on wall using the base as a template.
  4. Movement base out of the way. Drill mounting holes.
  5. Fasten base loosely to the wall, as shown in fig. 1, using two mounting screws. Place a level against the lesser of the the base, adjust until level, and so tighten screws. (Leveling is for  appearance only and will not bear upon thermostat operation.) If y'all are using existing mounting holes, or if holes drilled are besides large and practice not permit yous to tighten base snugly, use plastic spiral anchors to secure the subbase.White-Rodgers 1F87-361 Electronic Digital Thermostat - fig 1
  6. Push excess wire into the wall and plug the hole with a fire-resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.

Bombardment LOCATION
ii "AA" alkaline batteries are included in the thermostat at the factory with a battery tag to prevent power drainage. You must remove the battery tag to engage the batteries.
If "BATT" or "Change Change" is displayed, the batteries are low and should exist replaced with fresh "AA" Energizer ® alkaline batteries. To supersede batteries, install the batteries along the tiptop of the base (see Fig. 1). The batteries must be installed with the positive (+) stop to the left.

HYDRONIC (HOT H2o OR STEAM)
HEATING SYSTEMS
This thermostat is set to operate properly with a forced-air heating system. If you accept a hydronic heating system (a system that heats with hot water or steam), y'all must set the thermostat to operate properly with your system. Change the second option in the configuration bill of fare to SL (see CONFIGURATION MENU, page 4).

CHECK THERMOSTAT OPERATION
If at any fourth dimension during testing your system does non operate properly, contact a qualified service person.

Plow on ability to the system.

Fan Operation
If your arrangement does non have a Chiliad last connection, skip to Heating Arrangement.

  1. Movement FAN switch to ON position. The blower should begin to operate.
  2. Move FAN switch to AUTO position. The blower should end immediately.

INSTALLATION

White-Rodgers 1F87-361 Electronic Digital Thermostat - fig 6 White-Rodgers 1F87-361 Electronic Digital Thermostat - fig 7

‡The 24 Volt neutral connection to terminal C on the thermostat is not required if the batteries are replaced once a year with fresh "AA" Energizer ® alkaline batteries.

Heating System

  1. Movement Organization switch to HEAT position. If the heating system has a standing pilot, be sure to lite it.
  2. Printing to conform thermostat setting higher up room temperature. The heating system should begin to operate.
  3. Printing to adapt thermostat setting below room temperature. The heating organization should finish operating.

Cooling Arrangement
Warning Icon CAUTION
To forestall compressor and/or holding harm, if the outdoor temperature is below 50°F, DO Non operate the cooling system.

  1. Move SYSTEM switch to COOL position.
  2. Press to adjust thermostat setting beneath room temperature.
    The blower should come on immediately on loftier speed, followed by cold air circulation
  3. Press to arrange thermostat setting above room temperature. The cooling system should stop operating.

Functioning

Earlier you brainstorm programming your thermostat, y'all should be familiar with its features and with the display and the location and operation of the thermostat buttons.
Your thermostat consists of two parts: the thermostat embrace and the base of operations. To remove the cover, pull information technology straight out from the base of operations. To replace the cover, line upwards the cover with the base and press until the embrace snaps onto the base of operations.

The Thermostat Buttons and Switches

  1. Raises temperature setting.
  2. Lowers temperature setting.
  3. TIME button.
  4. PRGM (program) push button.
  5. RUN (run program) button.
  6. Hold temperature button.
  7. FAN switch (ON, AUTO).
  8. SYSTEM switch (Cool, OFF, Heat).
    The Display
  9. Indicates day of the calendar week.
  10. Flame icon ( ) is displayed when the SYSTEM switch is in the Heat position. Snowflake icon ( )is displayed  (non-flashing) when the SYSTEM switch is in the COOL
    position. Snowflake is displayed (flashing) if the thermostat is in lockout mode to prevent the compressor from cycling as well quickly.
  11. Displays "BATT" or "CHANGEChange " when the 2 "AA" batteries are depression and should be replaced. Just "BATT" or "CHANGE Change" and "LO" in the minute's field are displayed when batteries are low with no system ability.
  12. Alternately displays electric current time and temperature. Displays "LO" in the minute's field when batteries are low.
  13. The discussion "Hold" is displayed when the thermostat is in the Hold mode. "HOLD" is displayed flashing when the thermostat is in a temporary HOLD Manner.
  14. Displays currently programmed fix temperature (this is blank when System switch is in the OFF position).
  15. Displays "FLTR" when the organisation has run for the pro-gram filter time flow as a reminder to alter or make clean your air filter.

CONFIGURATION MENU

The configuration bill of fare allows you lot to fix sure thermostat operating characteristics to your system or personal requirements. Press RUN to make sure the thermostat is in the run program mode, and so press PRGM and RUN at the aforementioned fourth dimension to enter the configuration menu. The display will evidence the first particular in the configuration menu.  The configuration bill of fare tabular array summarizes the configuration options. An explanation of each pick follows.

White-Rodgers 1F87-361 Electronic Digital Thermostat - fig8

Press Agree to change to the next carte item or press Time to go back to the previous detail in the carte. To exit the menu and return to the program operation, press  RUN. If no keys are pressed within fifteen minutes, the thermostat will revert to normal functioning.

  1. Select Temporary Hold Fourth dimension – The thermostat tin concur any temperature you set information technology to for the corporeality of time you select on this option. Your choices are 0:00 to eight:00 hours in  xv-minute increments. 0:00 disables the function
    Example:
    1. You take selected three:00 hours for the Temporary Hold time catamenia.
    ii. With the thermostat set to Heat or Cool, press HOLD for approximately five seconds until Hold time (3:00 indicating 3 hours) appears as a ready reminder.
    three. Afterwards releasing the button, "HOLD" on the display will blink.
    iv. Use or to set the temperature to your preference- ence. The thermostat volition maintain this temperature setting for 3 hours with "Agree" blinking to remind you it is on Temporary  Concord. After 3 hours the thermostat will go back to the programmed temperature and "HOLD" will no longer blink or display.
  2. Select FA or SL (Fast or Slow) Heating Cycle Rate – The FA setting is frequently used for gas, oil or electrical heat. The SL setting produces a longer heating bicycle which is normally for hot water or steam (hydronic) systems. Both settings produce very accurate temperature control and can be set to your personal preference. FA cycles the organization but under one°F and the SL setting cycles at approximately i.5°F.
  3. Select backlit display – The display backlight improves brandish contrast in depression lighting weather. Selecting backlight ON volition keep the calorie-free on for a short period of fourth dimension later on any key is pressed. Selecting OFF volition keep the light off.
    Configuration Card
    Footstep Press Button(s) Displayed (Factory Default) Press ∧or ∨ to select: COMMENTS
    1 PRGM
    and RUN
    Hold
    (0:00)
    0 to 8 hrs (in

    15-minute increments)

    Select temporary Concord time
    2 Agree, 6 4

    (FA)

    SL Select FA or SL (Fast or Boring) heating bike rate
    3 HOLD, d-L
    (ON)
    OFF Select display backlight OFF or ON
    4 Concur, E
    (ON)
    OFF Select Energy Direction Recovery OFF or ON
    5 HOLD' Filter
    (000)
    0 to 1950 hours
    (in 50-hour increments)
    Select filter replacement run time
    6 Concur, LOC (OFF) ON Select compressor lockout OFF or ON
    7 Concur, 0 How-do-you-do
    (0)
    iv LO to
    iv HI
    Select temperature brandish adjustment higher or lower
    8 HOLD' (F) C Select temperature display to F or C
    9 RUN Returns to normal functioning

    * Press HOLD to accelerate to next item or Time to move backward to the previous particular

  4. Select Energy Management Recovery OFF or ON –
    Energy Direction Recovery (EMR) causes the thermostat to first heating or cooling early to make the building temperature reach the plan setpoint at the time y'all specify. Heating will start 5 minutes early on for every 1° of temperature required to reach the setpoint. Cooling allows more time per caste because information technology takes longer to reach temperature.
    Case: You select EMR and have your heating programmed to 65° at dark and 70° at vii AM. If the building temperature is 65° the departure betwixt 65°  and seventy° is 5°. Allowing five minutes per degree the thermostat setpoint will change to 70° at 6:35 AM.
  5. Select filter replacement run time – The thermostat will display "FLTR" later a set fourth dimension of operation. This is a reminder to change or clean your air filter. This fourth dimension can be set from 0 to 1950 hours in fifty-hour increments. A selection of 000 volition cancel this characteristic. When "FLTR" is displayed, you can clear information technology by pressing HOLD and RUN at the same time. This resets the timer and starts counting the hours until the next filter change. Changing the time in the menu also resets the timer.
  6. Select Compressor Lockout LOC OFF or ON – Selecting – LOC ON will cause the thermostat to wait 5 minutes before turning on the compressor if the heating and the cooling system lose power. It will likewise wait v minutes minimum betwixt cooling cycles. This is intended to help protect the compressor from short cycling. Some newer compressors already take a fourth dimension delay congenital-in and do not require this feature.  Your compressor manufacturer can tell yous if the feature is already nowadays in their system. When the compressor time filibuster occurs it will wink the (snowflake icon) for about five minutes so turn on the compressor.
  7. Select Temperature Display Aligning 4 LO to 4 HI – This allows you to adjust the room temperature brandish iv° higher or lower. Your thermostat was accurately calibrated at the factory merely yous have the selection to alter the display temperature to friction match your previous thermostat.
  8.  Select F° or C° Readout – Changes the display readout to Centigrade or Fahrenheit as required.

OPERATING FEATURES

Now that y'all are familiar with the thermostat buttons and brandish, read the post-obit information to learn nearly the many features of the thermostat.

  • SIMULTANEOUS HEATING/COOLING Plan STORAGE — When programming, you lot can enter both your heating and cooling programs at the same time.  In that location is no demand to reprogram the thermostat at the showtime of each season.
  • TEMPERATURE OVERRIDE — Press or until the display shows the temperature you want.  The thermostat volition override electric current programming and keep the room temperature at the selected temperature until the adjacent program flow begins. Then the thermostat will automatically revert to the plan.
  • Concord TEMPERATURE — The thermostat tin hold whatsoever temperature inside its range for an indefinite menses without reverting to the programmed temperature.  Momentarily press the HOLD push. "HOLD" volition be displayed. Then choose the desired temperature past pressing or . The thermostat will hold the room temperature at the elected setting until you press the RUN button to start the program operation once more.
  • CONFIGURATION Carte — This allows you to customize certain thermostat options.

PROGRAMMING YOUR THERMOSTAT

This department will help you plan your thermostat's program to meet your needs. For maximum comfort and efficiency, continue the following guidelines in mind when planning your program.

  • When heating (cooling) your building, program the temperatures to exist cooler (warmer) when the building is vacant or during periods of depression activity.
  • During early morning hours, the need for cooling is usually minimal.

Planning Your Programme
Look at the factory preprogrammed times and temperatures are shown in the sample schedule. If this programme will suit your needs, simply press the RUN push to begin running the factory preset program. If you want to change the preprogrammed times and temperatures, follow these steps.
Determine the fourth dimension periods and temperatures for your daily programs. Y'all must program four periods for both the weekday and weekend programs. However, y'all may apply the same heating and cooling temperatures for sequent time periods. You tin choose to start imes, heating temperatures, and cooling temperatures independently for each solar day programs (for example, you may select 5:00 AM and 70° equally the Monday 1st menses heating start time and temperature, and also choose 7:00 AM and 76° every bit the Monday 1st period cooling start time and temperature).

Utilise the post-obit tabular array o plan your program fourth dimension periods and the temperatures yous want during each period. Fill in the complete table to have a tape of your programs.

Inbound Your Program

Follow these steps to enter the heating and cooling programs you have selected.

Set Current Time and 24-hour interval

  1. Press the TIME button once. The display will prove the 60 minutes only.  PM
    EXAMPLE:White-Rodgers 1F87-361 Electronic Digital Thermostat -12
    SAMPLE
    Heating/Cooling Schedule Plan (Factory Plan)
    Menstruum ALL DAYS OF THE WEEK
    Start Fourth dimension Temperature
    Heat 1ST 6:00 AM 70 F
    2ND eight:00 AM 62 F
    tertiary 5:00 PM 70 F
    quaternary 10:00 PM 62 F
    Absurd 1ST half dozen:00 AM 78 F
    second 8:00 AM 85 F
    tertiary 5:00 PM 78 F
    4TH 10:00 PM 82 F
  2. Press and concord either or until yous attain the correct hour and AM/PM designation (AM begins at midnight; PM begins at apex).
  3.  Press TIME in one case. The brandish window will show the minutes only.
    Instance: White-Rodgers 1F87-361 Electronic Digital Thermostat -EXAMPLE
  4. Printing and concord either or until yous reach the correct minutes.
  5. Press Fourth dimension in one case. The display will bear witness the day of the week.
  6. Pressor until yous accomplish the electric current day of the week.
  7. Printing RUN once. The display will show the right time and room temperature alternately.

Enter Heating Program

  1. Motility the SYSTEM switch to Rut.
  2. Press PRGM once. "MO" (indicating Monday program) will appear in the display. Likewise displayed are the currently programmed offset time for the 1st heating period and the currently programmed temperature (flashing).
    Case:White-Rodgers 1F87-361 Electronic Digital Thermostat -6
    This display window shows that for Monday'south 1st heating period, the start time is 6:00 AM, and 70° is the programmed temperature (this case reflects mill preprogramming).
  3. Press or to change the displayed temperature to your selected temperature for Monday'south 1st heating program period.
  4. Press Fourth dimension once (the programmed time will wink). Press or until your selected start fourth dimension for Monday's 1st heating program period appears. The time volition alter in 15-minute increments. When your selected time is displayed, press Time once more to return to the change temperature mode.
  5. Press PRGM once. The currently programmed start time and setpoint temperature for Mon's 2nd heating program catamenia will appear.
  6. Echo steps 3 and 4 to select the start time and heating temperature for Monday's 2d heating program menstruation.
  7. Repeat steps iii through 5 for the 3rd and quaternary heating program periods. Monday heating programs are now complete.
    Menses 1 PERIOD 2 Menstruum three PERIOD 4
    HEAT COOL Rut Absurd HEAT Absurd HEAT Absurd
    Drne Temp Time Temp Time Temp Fourth dimension Temp Fourth dimension Temp Time Temp Time Temp Time Temp
    Mon
    Tues
    Wed
    Thur
    Fri
    Sat
    Sun

    Heating/Cooling Schedule Plan
    Annotation
    If y'all are programming your thermostat for the offset time and y'all want to program for all days of the week to be the same every bit Mon's program, printing RUN or Concord at this point, and proceed to Enter Cooling Plan. (This simplified Copy DAY feature only works the kickoff time you program your thermostat.
    If yous desire to copy ane twenty-four hours'southward programming to a specific twenty-four hours programming, refer to COPY 24-hour interval FUNCTION in OPERATING FEATURES. If you are changing your thermostat'south programming, you must program each twenty-four hour period separately.)

  8. Press HOLD once. "TU" (indicating Tuesday plan) volition appear in the display, along with the showtime time for the 1st heating period and the currently programmed temperature.
  9. Repeat steps iii through 7 to consummate Tuesday's heating programming.
  10. Continue entering each day's programming until all heating periods fourth dimension and temperatures take been entered.
  11. When you take completed entering your heating program, Printing RUN.

Warning Icon CAUTION
If the outside temperature is below 50°F, disconnect ability to the cooling system earlier programming. Energizing the air conditioner compressor during cold weather may cause personal injury or property damage.

  1. Move System switch to COOL position.
  2. Follow the procedure for entering your cooling program, using your selected cooling times and temperatures.

CHECK YOUR PROGRAMMING
Follow these steps to check your thermostat programming one final time before beginning the thermostat performance.

  1. Move SYSTEM switch to Heat position.
  2. Press PRGM to view the 1st Mon heating period time and temperature. Each time you printing PRGM, the next heating period time and temperature volition exist displayed in sequence for Mon. Printing HOLD to display Tuesday's 1st heating catamenia, and press PRGM to view each of the remaining Tuesday's heating period times and temperatures. To view each twenty-four hour period's heating program, press Concur to change day and and then press PRGM to look at each programming menstruum for the day. (You may change any time or temperature  during this procedure.)
  3.  Printing RUN.
  4.  Move SYSTEM switch to COOL position.
  5. Repeat step ii to check the cooling program.
  6. Motility SYSTEM switch to Estrus or COOL and printing RUN to begin program operation.
    YOUR THERMOSTAT IS At present COMPLETELY PROGRAMMED AND READY TO PROVIDE MAXIMUM COMFORT AND EFFICIENCY!

TROUBLESHOOTING

Reset Operation
If a voltage spike or static discharge blanks out the brandish or causes erratic thermostat functioning yous can reset the thermo- stat past pressing, and TIME at the same time. This also resets the factory defaults to the configuration menu and program. If the thermostat has power, has been reset, and still does not function correctly contact your heating/cooling service person or place of purchase. Batteries For optimum performance, nosotros recommend replacing batteries once a year with fresh "AA" Analeptic ®
element of group i batteries.

Symptom Possible Crusade Corrective Activity
No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker.
ii. Furnace power switch to OFF.
3. Furnace blower compartment door or panel loose or not properly installed.
Replace fuse or reset the breaker.
Turn the switch to ON.
Replace door console in the proper position to appoint safety interlock or door switch.
No Heat i. Airplane pilot lite not lit.
ii. Arrangement Switch not set up to Rut.
3. Loose connectedness to thermostat or system.
4. Furnace Lock-Out Condition. Heat may likewise be intermittent.
5. Heating System requires service or the thermostat requires replacement.
Re-light pilot.

Set up Arrangement Switch to Rut and enhance setpoint to a higher place room temperature.
Verify thermostat and system wires are securely attached. Many furnaces have safety devices that shut the system down when lock-out condition occurs. If the estrus works intermittently contact the furnace manufacturer or local service person for assistance.
Diagnostic:  Fix Organisation Switch to HEAT and enhance the setpoint higher up room temperature. Within a few seconds, the thermostat should make a soft click sound. This sound usually indicates the thermostat is operating properly.  f the thermostat does not click, try the reset operation listed above. If the thermostat does non click afterwards being reset contact your heating and cooling ervice person or identify of purchase fora replacement. If the thermostat clicks,  ontact the furnace manufacturer or a service person to verify the heating ystem is operating correctly.

No Cool one. Arrangement Switch not set to COOL below
two. Loose connection to thermostat or system.
3. Cooling Organisation requires service or thermostat requires replacement.
Set SYSTEM Switch to COOL and lower setpoint room temperature.   Verify thermostat and arrangement wires are securely attached. Same procedure every bit diagnostic for No Heat condition except set the thermostat to COOL and lower the setpoint below the room temperature.  At that place may be up to a v-minute filibuster earlier the thermostat clicks in Cooling if the compressor lock-out option is selected in the configuration carte du jour (Particular 6).
Estrus, Cool or Fan Runs Constantly. 1. FAN Switch gear up to Fan ON.
ii. Possible short in the wiring.
three. Possible brusk in thermostat.
4. Possible brusque in Rut/Cool/Fan organisation.
Check each wire connection to verify they are not shorted or touching together. No bare wire should stick out from under terminal screws. Attempt resetting the thermostat. If the condition persists the manufacturer of your system or service person can instruct you lot on how to exam the Heat/  Absurd system for correct functioning. If the system operates correctly, replace the thermostat.
Furnace Cycles Too Fast or Likewise Slow (narrow or  wide temperature swing) 1. The location of the thermostat and/or the size of the Heating System may  be influencing the cycle rate. Item ii in the Configuration Carte du jour is the adjustment that controls the bike rate. If an acceptable cycle rate is non achieved using the FA  (Fast)  or SL (Slow) adjustment contact a local service person for boosted suggestions.
Cooling Cycles Too Fast or As well Slow (narrow or  wide temperature swing) 1. The location of the thermostat and/or the size of the Cooling System may be influencing the cycle rate. The cycle rate for cooling is stock-still and can not be adjusted. Contact a local service person for suggestions.
Thermostat Setting and Thermometer Disagree ane. Thermostat thermometer setting requires adjustment. The thermometer can be adapted +/- 4 degrees as listed in particular 7 of the  Configuration Card. No other adjustment is possible.
Clock Loses or Gains Time 1. Loss of power to the thermostat and low batteries. The thermostat volition maintain its program in memory fifty-fifty with no power/no batteries only the clock fourth dimension will be incorrect when power is restored. See No Heat/No Cool/No Fan (common problems) above for items to check in the system.
Rut or Absurd Starts Early on 1. EMR activated Run across Configuration Bill of fare (Detail 4).
Thermostat Does Not Follow Programme 1. AM or PM set incorrectly in the plan.
2. AM or PM set incorrectly on the clock.
3. Voltage spike or static discharge.
Cheque the current clock and program settings including the AM or  PM designations for each time period. If a voltage spike or static discharge occurs utilise the Reset Functioning listed to a higher place.
Blank Display and/or Keypad Not

Responding

i. Loss of power and dead batteries.

2. Voltage Spike or Static Discharge.

Replace batteries and cheque the heat/cool system for proper operation. If a voltage spike or static discharge occurs employ the  Reset Functioning listed above.

HOMEOWNER HELPLINE: 1-888-725-9797 Emerson logo White-Rodgers logo

white-rodgers.com
emersonclimate.com

Ezoic

White-Rodgers is a business of Emerson Electrical Co.
The Emerson logo is a trademark and service mark of Emerson Electrical Co.

Documents / Resources

References

Source: https://manuals.plus/white-rodgers/1f87-361-electronic-digital-thermostat-manual

0 Response to "How To Set White Rodgers Thermostat"

Post a Comment

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel